Installing a USB hypervisor key

To install a USB hypervisor memory key in the server, complete the following steps:
1. Locate the USB hypervisor connector on the USB connector board in the server.
2. Push down the blue locking collar on the USB hypervisor connector (the
3. Insert the hypervisor memory key into the USB hypervisor connector.
4. Pull up the blue lock on the USB hypervisor connector to the locked position, to
5. Install the server cover (see "Installing the cover" on page 146).
6. Reconnect the external cables; then, reconnect the power cords and turn on the
Note: You will have to configure the server to boot from the hypervisor USB drive.
See "Configuring the server" on page 234 for information about enabling the
hypervisor memory key.

Removing a ServeRAID controller battery from the remote battery tray

To remove a ServeRAID controller battery from the remote battery tray, complete
the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and peripheral devices and disconnect all power cords and
3. Remove the cover (see "Removing the cover" on page 145).
4. Remove the PCI riser-card assembly (see "Removing the PCI riser-card
5. Remove the remote battery tray from the PCI riser-card assembly:
170
IBM System x3630 M3 Type 7377: Problem Determination and Service Guide
unlocked position).
secure the memory key in position.
peripheral devices and the server.
on page 133.
external cables.
assembly" on page 150).
a. Carefully disconnect the remote battery cable from the battery.

Advertisement