IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual page 48

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
A newly installed hard disk drive
is not recognized.
Multiple hard disk drives fail.
32
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Action
1. Observe the associated amber hard disk drive status LED. If the LED is lit, it
indicates a drive fault.
2. If the LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert
the drive, making sure that the drive assembly connects to the hard disk drive
backplane.
3. Observe the associated green hard disk drive activity LED and the amber
status LED:
v If the green activity LED is flashing and the amber status LED is not lit, the
drive is recognized by the controller and is working correctly. Run the DSA
hard disk drive test to determine whether the drive is detected.
v If the green activity LED is flashing and the amber status LED is flashing
slowly, the drive is recognized by the controller and is rebuilding.
v If neither LED is lit or flashing, check the hard disk drive backplane (go to
step 4).
v If the green activity LED is flashing and the amber status LED is lit, replace
the drive. If the activity of the LEDs remains the same, go to step 4. If the
activity of the LEDs changes, return to step 1.
4. Make sure that the hard disk drive backplane is correctly seated. When it is
correctly seated, the drive assemblies correctly connect to the backplane
without bowing or causing movement of the backplane.
5. Reseat the backplane power cable and repeat steps 1 through 3.
6. Reseat the backplane signal cable and repeat steps 1 through 3.
7. Suspect the backplane signal cable or the backplane:
v If the configuration has eight hot-swap bays:
a. Replace the affected backplane signal cable.
b. Replace the affected backplane.
v If the configuration has 12 hot-swap bays:
a. Replace the backplane signal cable.
b. Replace the backplane.
c. Replace the SAS expander card.
8. Run the DSA tests for the SAS controller and hard disk drives:
v If the controller passes the test but the drives are not recognized, replace the
backplane signal cable and run the tests again.
v Replace the backplane.
v If the controller fails the test, disconnect the backplane signal cable from the
controller and run the tests again.
v If the controller fails the test, replace the controller.
9. See "Problem determination tips" on page 108.
Make sure that the hard disk drive, SAS RAID controller, and system-board tray
device drivers and firmware are at the latest level.
Important: Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.

Advertisement

Table of Contents
loading

Table of Contents