3.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
*1
The bit number can be set only when specifying the bit
Device
of word device.
Displays the device type and setting range which are
Information
selected in [Device].
*1
The uppermost bit is b0 and the lowermost bit is b15.
POINT
POINT
POINT
Device settings of HITACHI PLC
(1) When setting a bit device
Set the device using the format of address (word
unit) + bit number (0 to F).
Device name
(2) When setting a word device
For external input (XW), external output (YW),
internal register (RW), extended internal register
(MW, AW), keep relay (KW), on-delay timer (TW),
one-shot timer (UW), up-down counter (CW),
global link register (GW), event register (EW),
system register (SW), transfer register (JW), and
receive register (QW), set as follows.
Device name
Information
Bit position (0 to F)
Address (word units)
Fixed to 0
Address (word units)
3.6.1

HITACHI S10mini/S10V

Device name
External input (X)
External output (Y)
Internal register (R)
Keep relay (K)
Extended internal register
(M)
Extended internal register
(A)
On-delay timer (T)
One-shot timer (U)
Up-down counter (C)
*6
Global link register (GL)
Event register (E)
*1
System register (S)
Transfer register (J)
Receive register (Q)
Specified bit of the
following word devices
One-shot timer, up-down
counter, function data
Word device bit
register, function work
register, extended function
work register, backup work
register, backup long-word
External input (XW)
External output (YW)
Internal register (RW)
Extended internal register
MW000 to MWFF0
(MW)
Extended internal register
(AW)
Keep relay (KW)
On-delay timer (TW)
3. CONNECTION TO HITACHI PLC
3.6 Device Range that Can Be Set
Device
No.
Setting range
represen
tation
X000 to XFFF
Y000 to YFFF
R000 to RFFF
K000 to KFFF
M000 to MFFF
A000 to AFFF
Hexadec
T000 to T1FF
imal
U000 to U0FF
C00 to CFF
GL000 to GLFFF
E000 to EFFF
S000 to SBFF
J000 to JFFF
Q000 to QFFF
work register
XW000 to XWFF0
YW000 to YWFF0
RW000 to RWFF0
Hexadec
imal
AW000 to AWFF0
KW000 to KWFF0
TW000 to TW1F0
3 - 9