Ethernet setting
(1) Ethernet connection type: FETCH/WRITE
This section describes the Ethernet setting for the
communication driver SIEMENS S7 (Ethernet).
Item
Description
The host is displayed. (The host is
Host
indicated with an asterisk (*).)
Set the network No. of the
N/W No.
connected Ethernet module.
(Default: blank)
Set the station No. of the connected
*1
Ethernet module.
PLC No.
(Default: blank)
Type
SIEMENS S7 (fixed)
Set the IP address of the connected
IP Address
Ethernet module.
(Default: blank)
Set the FETCH port No. of the
FETCH Port
connected Ethernet module.
No.
(Default: 2000)
For the WRITE port No. of the
connected Ethernet module, the
value that the FETCH port No. is
WRITE Port No.
incremented by one is set
automatically.
(Default: 2001)
Communication TCP (fixed)
*1
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
 Communication detail settings
(2) Ethernet connection type: OP communication
This section describes the Ethernet setting for the
communication driver SIEMENS OP (Ethernet).
Item
Host
Set value
N/W No.
PLC No.
1 to 239
Type
1 to 64
SIEMENS S7
IP Address
(fixed)
PLC side IP
Port No.
address
Connection
No./Rack No.
1024 to 65534
Module
Position/Slot
*1
No.
1025 to 65535
Communication TCP (fixed)
TCP (fixed)
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
14. CONNECTION TO SIEMENS PLC
Description
The host is displayed. (The host is
indicated with an asterisk (*).)
Set the network No. of the
*2
connected Ethernet module.
(Default: blank)
Set the station No. of the connected
Ethernet module.
(Default: blank)
Set the PLC type to be connected.
Set the IP address of the connected
Ethernet module.
(Default: blank)
102 (fixed)
Set the Connection No./Rack No. set
on the PLC side.
*1
(Default: 0)
Set the Module Position/Slot No. set
on the PLC side.
(Default)
S7-200 OP: 0
S7-300/400 OP: 2
*1
Connection No./Rack No. and Module Position/Slot No. are
unnecessary for S7-1200 OP.
*2
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
 Communication detail settings
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GT
User's Manual
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
14.3 Ethernet Connection
9
10
Set value
11
1 to 239
1 to 254
S7-200 OP
S7-300/400 OP
S7-1200 OP
12
PLC side IP
address
102 (fixed)
0 to 7
S7-200
13
OP: 0 to 6
S7-300/400
OP: 0 to 31
TCP (fixed)
14
15
16
14 - 13