3.4 GOT Side Settings

3.4.1
Setting communication
interface (Communication
settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: HITACHI
• Controller Type: HITACHI S10mini/S10V
• I/F: Interface to be used
• Driver: HITACHI S10mini/S10V
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

3.4.2 Communication detail settings

Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2I/F communication setting
3.4.2
Make the settings according to the usage environment.
3.
4.
Item
Transmission
Speed
Click!
Data Bit
Stop Bit
Parity
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
3. CONNECTION TO HITACHI PLC
Communication detail settings
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 19200bps)
Set this item when change the data
length used for communication with
the connected equipment.
(Default: 8bits)
Specify the stop bit length for
communications.
(Default: 8bits)
Specify whether or not to perform a
parity check, and how it is performed
during communication.
(Default: Odd)
Set the number of retries to be
performed when a communication
error occurs.
(Default: 0time)
Set the time period for a
communication to time out.
(Default: 3sec)
Set this item to adjust the
transmission timing of the
communication request from the
GOT.
(Default: 0)
The communication interface setting can be
changed on the Utility's [Communication Settings]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GT
User's Manual
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
3.4 GOT Side Settings
1
2
3
Range
9600bps,
4
19200bps,
38400bps,
57600bps,
115200bps
7bits/8bits
5
1bit/2bits
None
Even
Odd
0 to 5times
6
3 to 30sec
0 to 300m
7
8
3 - 7