Ethernet Connection; System Configuration For Connecting To Simatic S7-300/400 Series (Ethernet Connection Type: Fetch/Write) - Mitsubishi Electric GOT1000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

14.3 Ethernet Connection

14.3.1 System configuration for connecting to SIMATIC S7-300/400 series
(Ethernet connection type: FETCH/WRITE)
SIMATIC
Ethernet
S7-300/400
Module
series
PLC
Ethernet
Series
*4
Module
CP343-1 IT
SIMATIC
CP343-1
S7-300
CP343-1 Lean
CP343-1 Advanced
SIMATIC
CP443-1 IT
S7-400
CP443-1
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*4
Product manufactured by Siemens AG. For details of the product, contact Siemens AG.
*5
If the number of GOTs increases, the communication becomes highloaded, and it may affect the communication performance.
*6
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
Connection cable
Connection cable
*1
Cable model
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP):
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP):
Category 5 and 5e
GT16 User's Manual (Hardware)
GOT
GOT
Maximum
segment
Option device
Model
*2
length
- (Built into GOT)
100m
GT15-J71E71-100
- (Built into GOT)
100m
GT15-J71E71-100
14. CONNECTION TO SIEMENS PLC
14.3 Ethernet Connection
Communication driver
Ethernet(
SIEMENS S7
), Gateway
Number of connectable
equipment
*3
When PLC:GOT is N:1
*6
The following shows the
number of PLCs for 1 GOT
<For GT16, GT14>
16 or less
<For GT15, GT12>
*6
5 or less
When PLC:GOT is 1:N
The following shows the
number of GOTs for 1 PLC
*6
32 or less
(recommended
to 16 or less)
14 - 9
9
10
11
12
13
14
15
16

Advertisement

Table of Contents
loading

Table of Contents