Yaskawa Cp9200Sh/Mp900; Yaskawa Cp9200 (H); Yaskawa Cp9300Ms (Mc Compatible) - Mitsubishi Electric GOT1000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

*4
SR and SW indicate registers (virtual register) compatible to
the data format where internal data of PLC is displayed using
R or W.
The following shows the difference between the display
values of SR, SW and those of R, W corresponding to the
values of PLC internal data.
PLC internal data (16 bit)
9999
1001
1000
999
0
-1
-999
-1000
-1001
-9999
*5
The internal coil N1 to N1536 can be set as O513 to O2048.
However, setting must not exceed O1 to O512 and O513 to
O2048.
*6
Change the input relay "10001 to 14096" to "I1 to I4096" for
setting. (When set in default)
*7
Only reading is possible.
6.4.2

YASKAWA CP9200SH/MP900

Device name
Setting range
*1
MB000000 to MB32767F
Coil (MB)
Input relay (IB)
MB000000 to MB32767F
Specified bit of the following
*2
word devices
Word device bit
input register, holding register
Input register
IW0000 to IW7FFF
(IW)
Holding register
MW0 to MW32767
(MW)
*2
MB0 to MB32767
Coil (MB)
*2
IB000 to IBFFF
Input relay (IB)
*1
MB40960 to MB32767F is available for MP-940 only.
*2
This is not supported by GT10.
SR, SW
R, W
9999
9999
1001
1001
1000
1000
999
999
0
0
-1
32769
-999
33767
-1000
33768
-1001
33769
-9999
42767
Device No.
representation
Decimal +
Hexadecimal
Hexadecimal
Hexadecimal
Decimal
Decimal
Hexadecimal
6.4.3

YASKAWA CP9200 (H)

Device name
Setting range
*3
OB000 to OB7FF
Coil (OB)
*3
IB000 to IB7FF
Coil (OB)
Specified bit of the following
*4
Word device bit
word devices
Input register
IW00 to IW7F
(IW)
Output register
OW00 to OW7F
(OW)
DW0 to DW2047
Data register
*1
(DW, ZD)
ZD0 to ZD2047
Common register
MW0 to MW7694
*2
(MW)
*4
Converting bit devices into word
Bit device word
*1
Setting is available only when CP-9200H is used.
*2
To use data registers of CPU #1 during operation of CP-
9200, copy them to MW0 to 7694.
*3
During operation of CP-9200H, specify the reference No.
and quantities so that they do not cover both OB*** and
IB***.
*4
This is not supported by GT10.
6.4.4
YASKAWA CP9300MS (MC
compatible)
Device name
Setting range
Coil (OB)
OB0 to OB1023
Input relay (IB)
IB0 to IB1023
Specified bit of the following
*1
Word device bit
word devices
Input register (I)
I0 to I63
Data register (M)
M0 to M2047
Output register
o0 to o63
(o)
*1
Converting bit devices into word
Bit device word
*1
This is not supported by GT10.
6. CONNECTION TO YASKAWA PLC
6.4 Device Range that Can Be Set
1
Device No.
representation
Hexadecimal
2
Hexadecimal
3
Decimal
4
5
Device No.
representation
Decimal
6
Decimal
7
8
6 - 33