Download  Print this page

Mitsubishi Electric GOT1000 Series Connection Manual Page 221

Graphic operation terminal.
Hide thumbs

Advertisement

Temperature
controller
Commun
Series
ication
Connection diagram number
Type
RS485 connection diagram 27)
UT52A
*5
UT55A
RS485 connection diagram 28)
RS-485
*6
UP55A
*7
UM33A
RS485 connection diagram 13)
*1
Including the cable length of the option devices.
*2
Connect it to the RS-232 interface (built into GOT). It cannot be mounted on GT1655 and GT155 .
For *3 to *8, only the products that meet the following conditions can be connected.
Annotation
*9
Connect it to the RS-232 interface (built into GOT).
*10
Product manufactured by MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED. For details of the product, contact
MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED.
Connection cable
Cable model
Max.
distance
1200m
(2-wire type)
1200m
(2-wire type)
1200m
(2-wire type)
Suffix code
Function
Open network
1 or 2
-
*3
-
1
2
-
Other than 3
1
*4
-
-
-
-
*5
1 or 2
-
2
-
*6
-
-
*7
1
-
*8
1
-
8. CONNECTION TO YOKOGAWA TEMPERATURE CONTROLLER
GOT
Option device
- (Built into GOT)
*10
FA-LTBGTR4CBL05 (0.5m)
*10
FA-LTBGTR4CBL10 (1m)
*10
FA-LTBGTR4CBL20 (2m)
GT15-RS4-TE
Optional suffix code
Product with two RS-485 communication ports (4-wire type/
Without "/LP"
2-wire type) and without the power supply for 24VDC sensor
Product with the open network port of RS-485
-
communication (4-wire type/2-wire type)
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product without the additional contact output points (DO)
-
and with the open network port of RS-485 communication
(4-wire type/2-wire type) (Standard code model)
Product with RS-485 communication port (4-wire type/2-wire
With "/CH3"
type) specified in the E3 terminal area option (Detailed code
model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports (4-wire type/
With "/LP"
2-wire type) and with the power supply for 24VDC sensor
Product with two RS-485 communication ports (4-wire type/
-
2-wire type) (Standard code model)
Product with the RS-485 communication port (4-wire type/2-
With "/C4"
wire type) specified in the E4 terminal area option (Detailed
code model)
Product with two RS-485 communication ports and without
With "/LP"
the power supply for 24VDC sensor
Product with two RS-485 communication ports (4-wire type)
Without "/LP"
and without the power supply of 24VDC sensor
8.2 System Configuration
Number of connectable
equipment
Model
Up to 31 temperature controllers
for 1 GOT
Remark
1
2
3
4
5
6
7
8
8 - 9

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric GOT1000 Series

Comments to this Manuals

Symbols: 0