(b) S7-200 Series
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and setting range which are
Description
selected in [Device].
POINT
POINT
POINT
Device settings of SIEMENS PLC (S7-200 series)
(1) When setting bit devices (except Timer and
Counter)
Set the device using the byte address (DEC) and
the bit address (0 to 7).
Device name
(c) SIEMENS OP (Ethernet)
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and setting range which are
Information
selected in [Device].
Set the monitor target of the set device.
Select this item to monitor the controller specified
Host
Network
as the host station in the GOT utility (setup).
Select this item to monitor a controller other than
Other
the one specified as the host station.
Description
Bit address (0 to 7)
Byte address (DEC)
Description
POINT
POINT
POINT
Device settings of SIEMENS PLC (S7-200/300/400/
1200 series, SIEMENS OP (Ethernet))
(1) When setting a bit device as a bit device
Set the device using the format of byte address
(DEC) + bit address (0 to 7).
Device name
(2) When setting a data register
Set the device using the format of data block
(DB) + data word (DW).
Device name
(3) Precautions when setting devices
(a) Preparing to set a data register
It is necessary to define the data block using a
peripheral software and sequence program,
before using a data register. Setting more
than one data block cannot be done for the
data register.
(b) Object that cannot be set Timer (current
value) (T)
Only one device can be set for the write target
of this device. Therefore, multiple devices,
such as, using the recipe function, etc.,
cannot be used.
(c) Notation method of the data registers with the
bit specification
The notation of the data registers with the bit
specification differs between the GOT and the
PLC. The following shows the
correspondence table.
Notation in GOT
DB1.DBW0.b0
DB1.DBW0.b1
:
DB1.DBW0.b7
DB1.DBW0.b8
:
DB1.DBW0.b15
DB1.DBW2.b0
:
DB1.DBW2.b7
DB1.DBW2.b8
:
DB1.DBW2.b15
:
14. CONNECTION TO SIEMENS PLC
14.4 Device Range that Can Be Set
9
10
Device number
Bit address (0 to 7)
Byte address (DEC)
11
Data word (DW) numbe
Data block (DB) numbe
12
13
14
Notation in PLC
DB1.DBX1.0
DB1.DBX1.1
:
15
DB1.DBX1.7
DB1.DBX0.0
:
DB1.DBX0.7
DB1.DBX3.0
:
DB1.DBX3.7
DB1.DBX2.0
16
:
DB1.DBX2.7
:
14 - 17