HINT
HINT
HINT
The rotary switch (address setting switch) is also used
for the data interval extension time setting.
The setting method is the same as that of the module
address.
For the data interval extension time, refer to the
following.
(4)Data interval extension time settings
(4) Data interval extension time settings
Set the data interval extension time as the following
procedure.
1.
Turn the power of the module OFF.
2.
Set the DIP switch 4 and 6 to ON and 5 to OFF.
3.
Set the data interval extension time using the rotary
switch (address setting switch).
For the setting method, refer to the following.
(3)Module address settings
4.
Turn the power of the module ON.
The FAIL/RUN lamp lights in green and the set time
becomes valid.
5.
Turn the power of the module OFF again and set the
DIP switches and rotary switch to the original position.

9.5.16 Connecting to SB1

Communication settings
Make the communication settings of SB1 using the
switch key on the front surface.
For the operation procedure, refer to the SB1 manual.
Item
Communication
0: RKC communication
protocol*2
1: MODBUS
*1*3
Device address
0 to 99
(Slave address)
0: 2400bps
1: 4800bps
*1*4
Communication speed
2: 9600bps
3: 19200bps
*1*5
0 to 5
Data bit configuration
*6
0 to 250ms
Interval time
*1
Adjust the settings with GOT settings.
*2
Select 1: MODBUS.
*3
When the setting value is 0, communication is not
performed.
*4
The communication speed cannot be set to 2400bps or
4800bps on the GOT side.
Select 2 or 3.
*5
For details on the data bit configuration, refer to the
following.
Set value
Data bit
0
1
2
Setting range
Parity bit
Stop bit
8
None
1
8
None
2
8
Even
1
9. CONNECTION TO RKC TEMPERATURE CONTROLLER
Set value
Data bit
3
4
5
*6
Set the maximum time from when the last character stop bit
is sent from the GOT side until the transmission cable
becomes ready to receive.

9.5.17 Connecting to B400

Communication settings
Make the communication settings of B400 using the
rotary switch key and the DIP switch.
For the operation procedure, refer to the B400 manual.
Item
Setting range
Unit address setting
*1
0 to 99
(CH1 to CH8)
4800bps?9600bps?1
Communication speed
9200bps?38400bps
Data bit configuration
0 to 5
Communication
RS-422A, RS-485
specification setting
Termination resistor
Enable, Disable
setting
*1
When the setting value is 98 or 99, the communication
address is the same as for 97.
(1) Rotary switch setting (SW1, SW2)
Set the unit address using the rotary switch.
Rotary switch
(Address setting switch)
SW1: Lower digit setting
(Set value x1)
SW2: Upper digit setting
Item
Unit address setting
The communication address is the rotary
(CH1 to CH4)
switch setting value + 1.
Unit address setting
The communication address is the rotary
(CH5 to CH8)
switch setting value + 2.
9.5 Temperature Controller Side Setting
Parity bit
Stop bit
8
Even
2
8
Odd
1
8
Odd
2
Settings
(1)Rotary switch setting
(SW1, SW2)
(2)DIP switch setting
(SW3)
(3)DIP switch settings
(SW4)
(Set value x10)
Setting range
9 - 47
9
10
11
12
13
14
15
16

Advertisement

Table of Contents
loading

Table of Contents