Installing a unit on another unit (Checking the unit installation position)

This section describes the precautions for installing units on another unit.
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you are
using. For the method for installing a unit on another unit, refer to the following.
Calculating consumed current
For using multiple extension units, a bar code reader, or a RFID controller, the total current for the extension units,
bar code reader, or RFID controller must be within the current that the GOT can supply.
For the current that the GOT can supply and the current for the extension units, bar code reader, or RFID controller,
refer to the following tables. Make sure that the total of consumed current is within the capacity of the GOT.
(1) Current supply capacity of the GOT
GT1695M-X
GT1685M-S
GT1675M-S
GT1675M-V
GT1675-VN,
GT1665M-S
GT1665M-V
GT1662-VN
GT1655-V
(2) Current consumed by an extension unit/barcode reader/RFID controller
GT15-QBUS,
GT15-75QBUSL,
GT15-ABUS,
GT15-75ABUSL,
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
GT15-RS2T4-9P
GT15-J71E71-100
GT15-J71GP23-SX
GT15-J71LP23-25
GT15-J71BR13
GT15-J61BT13
Bar code reader
GT15-PRN
GT16M-V4
GT15V-75V4
*1
Value used for calculating the current consumption of the multi-channel function.
For the specifications of the unit, refer to the manual included with the unit.
*2
When the GOT supplies power to a barcode reader or a RFID controller from the standard interface, add their consumed
current.(Maximum value is less than 0.3 A.)
1 - 20
1. PREPARATORY PROCEDURES FOR MONITORING
1.3 Option Devices for the Respective Connection
User's Manual of GOT used
Current supply
GOT type
capacity
GT1672-VN
Module type
GT15-QBUS2,
GT15-75QBUS2L
GT15-ABUS2,
GT15-75ABUS2L
(A)
2.4
GT1595-X
2.4
GT1585V-S
2.4
GT1585-S
2.4
GT1575V-S
2.4
GT1575-S
2.4
GT1575-V,
2.4
GT1565-V,
2.4
GT1555-V
1.3
GT1555-Q,
Consumed
current
(A)
*1
GT16M-R2
0.275
0.12
GT15V-75R1
0.29
GT16M-V4R1
0.33
GT15V-75V4R1
0.3
GT16M-ROUT
0.098
GT15V-75ROUT
0.224
GT16M-MMR
1.07
GT15-CFCD
0.56
GT15-CFEX-C08SET
0.77
GT15-SOUT
0.56
GT15-DIO
*2
GT15-DIOR
0.09
RFID controller
*1
GT15-80FPA
0.12
*1
0.2
Current supply
GOT type
capacity
GT1572-VN
GT1562-VN
GT1550-Q
Module type
(A)
2.13
1.74
1.74
2.2
2.2
2.2
2.2
1.3
1.3
Consumed
current
(A)
*1
0
*1
0.2
*1
0.12
*1
0.2
*1
0.11
0.11
*1
0.27
0.07
0.15
0.08
0.1
0.1
*2