4.3 Ethernet Connection

4.3.1

System Configuration for connecting to MICREX-SX SPH

Ethernet
MICREX-SX SPH
interface module
PLC
Ethernet
Model name
*3
interface module
SPH200
SPH300
NP1L-ET1
SPH2000
SPH3000
SPH2000
-
SPH3000
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
GT16 User's Manual (Hardware)
*4
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
Connection cable
Connection cable
*1
Cable model
Connection diagram number
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP):
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP):
Category 5 and 5e
GOT
GOT
Max.
Option device
Model
*2
distance
- (Built into
100m
GOT)
- (Built into
100m
GOT)
4. CONNECTION TO FUJI PLC
4.3 Ethernet Connection
Communication driver
Ethernet(
), Gateway
FUJI
Number of connectable
equipment
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1 PLC
128 or less
*4
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1 PLC 8
or less
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1 PLC
128 or less
*4
When PLC: GOT is 1: N
The following shows the
number of GOTs for 1 PLC
10 or less