Configuring The Hiper-Ring - Hirschmann RS20 Reference Manual

Gui graphical user interface industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Redundancy
6.1.1

Configuring the HIPER-Ring

Note: For the ring ports, select the following basic settings in the Basic
Settings:Port Configuration dialog:
Port type Bit rate
TX
100 Mbit/s
TX
1 Gbit/s
Optical
100 Mbit/s
Optical
1 Gbit/s
Table 94: Port settings for ring ports
Note: Configure all the devices of the HIPER-Ring individually. Before you
connect the redundant line, you must complete the configuration of all the
devices of the HIPER-Ring. You thus avoid loops during the configuration
phase.
Note: As an alternative to using software to configure the HIPER-Ring, with
devices RS20/30/40 and MS20/30 you can also use DIP switches to enter a
number of settings on the devices. You can also use a DIP switch to enter a
setting for whether the configuration via DIP switch or the configuration via
software has priority. The state on delivery is "Software Configuration". You
will find details on the DIP switches in the "Installation" user manual.
148
Autonegotiation
Port setting
(automatic
configuration)
off
on
on
on
off
on
on
on
6.1 Ring Redundancy
Duplex
100 Mbit/s full duplex (FDX)
-
100 Mbit/s full duplex (FDX)
-
RM GUI L2E
Release 8.0 05/2013