Basic Settings
1.7.2
Saving the Configuration
In the "Save" frame, you have the option to
save the current configuration on the device,
save the current configuration in binary form in a file under the specified
URL,
save the current configuration in binary form on the PC,
save the current configuration for the offline configurator on the PC in
XML format.
Note: For script configuration files, note the following characteristics:
If you save the configuration in a binary file, the device saves all
configuration settings in a binary file.
In contrast to this, the device only saves those configuration settings that
deviate from the default setting when saving to a script file.
When you load a configuration from a script file, delete the configuration
on the device first so that the script that is being loaded overwrites the
configuration default settings correctly.
If a configuration already exists on the device, the result is the loading of
a script file in a configuration involving the union of the settings which
differ from the default setting in the existing configuration or in the script
file. If you use this feature, remember that loading a script sets
configuration settings only to values that differ from the default setting.
To delete the configuration on a device, select "Current configuration" in
the "Delete" frame and click on "Delete configuration". The device
immediately deletes its current configuration from the volatile memory
(see on page 49 "Deleting a
volatile memory is kept, along with the IP address. Thus the device
remains reachable.
46
configuration"). The configuration in the non-
1.7 Load/Save
RM GUI L2E
Release 8.0 05/2013