Configuring The Mrp-Ring - Hirschmann RS20 Reference Manual

Gui graphical user interface industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Redundancy
6.1.2

Configuring the MRP-Ring

Note: To configure an MRP-Ring, you set up the network to meet your
demands. For the ring ports, select the following basic settings in the Basic
Settings:Port Configuration dialog:
Port type Bit rate
TX
100 Mbit/s
TX
1 Gbit/s
Optical
100 Mbit/s
Optical
1 Gbit/s
Table 96: Port settings for ring ports
Note: Configure all the devices of the MRP-Ring individually. Before you
connect the redundant line, you must have completed the configuration of all
the devices of the MRP-Ring. You thus avoid loops during the configuration
phase.
Note: If you have configured VLANs and you want to assign the MRP-Ring
configuration to a VLAN.
 Select a VLAN-ID > 0 in the VLAN field in the Redundancy:Ring
Redundancy dialog. Select this VLAN ID in the MRP-Ring configuration
for all devices in this MRP-Ring.
 Check the VLAN configuration of the ring ports: For all ring ports in this
MRP-Ring, select this corresponding VLAN ID and the VLAN
membership T in the static VLAN table.
 Avoid the VLAN ID = 0.
Note: If you are also using redundant ring/network coupling, make sure that
the device is transmitting VLAN 1 packets tagged on the two ring ports.
152
Autonegotiation
Port setting
(automatic
configuration)
off
on
on
on
off
on
on
on
6.1 Ring Redundancy
Duplex
100 Mbit/s full duplex (FDX)
-
100 Mbit/s full duplex (FDX)
-
RM GUI L2E