Basic Settings
In the "Manual Cable Crossing (Auto. Conf. off)" column, you assign the
connections of a TP port, if "Automatic Configuration" is deactivated for
this port. The possible settings are:
– enable: the device does not swap the send and receive line pairs of the
TP cable for this port (MDI).
– disable: the device swaps the send and receive line pairs of the TP
cable for this port (MDIX).
– unsupported: the port does not support this function (optical port, TP
SFP port).
In the "Flow Control" column, you checkmark this port to specify that flow
control is active here. You also activate the global "Flow Control" switch
(see on page 104 "Switching
Note: The device supports gigabit interfaces on copper ports with auto
negotiation enabled.
Note: The active automatic configuration has priority over the manual
configuration.
Note: When you are using a redundancy function, you deactivate the flow
control on the participating device ports. If the flow control and the
redundancy function are active at the same time, there is a risk that the
redundancy function will not operate as intended.
Note: The following settings are required for the ring ports in a HIPER-Ring:
Port type Bit rate
TX
100 Mbit/s
TX
1 Gbit/s
Table 6:
Port settings for ring ports
RM GUI L2E
Release 8.0 05/2013
Global").
Autonegotiation (automatic
configuration)
off
on
1.5 Port Configuration
Port setting
Duplex
on
full
on
-