Redundancy
Create new Ring Redundancies.
Configure existing Ring Redundancies.
Enable/disable the Ring Manager function.
Receive Ring information.
Delete the Ring Redundancy.
Note: Only one Ring Redundancy method can be enabled on one device at
any one time. When changing to another Ring Redundancy method,
deactivate the function for the time being.
Parameter
Meaning
Version
Select the Ring Redundancy version you want to use:
HIPER-Ring
MRP
Ring port No. In a ring, every device has 2 neighbors. Define 2 ports as ring ports to which the
neighboring devices are connected.
Module
Module identifier of the ports used as ring ports
Port
Port identifier of the ports used as ring ports
Operation
Value depends on the Ring Redundancy version used. Described in the
following sections for the corresponding Ring Redundancy version.
Table 93: Ring Redundancy basic configuration
RM GUI L2E
Release 8.0 05/2013
6.1 Ring Redundancy