Hirschmann RS20 Reference Manual page 198

Gui graphical user interface industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Diagnostics
The events which can be selected are:
Name
"Device Status"
Frame
"Trap
Configuration"
Frame
Generate Trap
"Monitoring"
Frame
Power supply ...
Temperature (°C)
Module removal
ACA removal
ACA not in sync
Connection error
Ring Redundancy
Ring/Network
coupling
Table 125:Device Status
198
Meaning
The device determines this status from the individual monitoring results.
It can have the values "Error" or "OK".
-
Activate this setting so the device sends a trap if it changes its device
status.
-
Monitor/ignore supply voltage(s).
Monitor/ignore temperature thresholds set
temperatures that are too high/too low
Monitor/ignore the removal of a module (for modular devices).
Monitor/ignore the removal of the ACA.
Monitor/ignore non-matching of the configuration on the device and on
a
the ACA
.
Monitor/ignore the link status (Ok or inoperable) of at least one port.
The reporting of the link status can be masked for each port by the
management
(see on page 32 "Port
monitored in the state on delivery.
Monitor/ignore ring redundancy (for HIPER-Ring only in Ring Manager
mode).
On delivery, ring redundancy is not monitored.
If the device is a normal ring subscriber and not the ring manager, it
reports the following:
nothing (for the HIPER-Ring)
detected errors in the local configuration (for Fast HIPER-Ring and
for MRP)
Monitor/ignore the redundant coupling operation.
On delivery, no monitoring of the redundant coupling is set.
For two-Switch coupling with control line, the slave additionally reports
the following conditions:
– Incorrect link status of the control line
– Partner device is also a slave (in standby mode).
Note: In two-Switch coupling, both Switches must have found their
respective partners.