View The Software Versions Presenton The Device; Restoring The Backup Version; Tftp Software Update - Hirschmann RS20 Reference Manual

Gui graphical user interface industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Basic Settings
1.4.1
View the software versions present
on the device
The dialog shows the existing software versions:
Stored Version:
The version of the software stored in the flash memory.
Running Version:
The version of the software currently running.
1.4.2

Restoring the Backup Version

"Restore" replaces the software version stored with the backup version of the
software. The relevant configuration files are replaced at the same time. A
cold start is required to make the software versions effective. A warm start
has no effect whatsoever.
 Once successfully replaced, activate the restored software:
Select the Basic settings: Restart dialog and perform a cold start.
In a cold start, the device reloads the software from the non-volatile
memory, restarts, and performs a self-test.
 Reload the graphical user interface in your browser to re-access the
device after restarting.
1.4.3

TFTP Software Update

For a tftp update you need a tftp server on which the software to be loaded
is stored.