HIPER-Ring
2.1 Configuring HIPER-Ring
Version 1
Set up the network to meet your requirements.
Note: Before you connect the redundant line, you must complete the
configuration of HIPER-Ring Version 1.
You thus avoid loops during the configuration phase.
Note: Configure each HIPER-Ring device.
Select the Redundancy:HIPER-Ring dialog.
Select Version 1.
Note: As an alternative to using software to configure HIPER-Ring
Version 1, with devices RS20/30/40 and MS20/30 you can also use a
DIP switch to enter a number of settings for HIPER-Ring Version 1. You
can also use this DIP switch to enter a setting for whether the configu-
ration via DIP switch or the configuration via software has priority. The
state on delivery is "Software Configuration".
For each device, you enter the desired ring ports 1 and 2.
The following settings are required for the ring ports (select the
Basic Settings:Port Configuration dialog):
Bit rate
Autonegotiation
(automatic configuration)
Port
Duplex
Table 2: Port settings for ring ports
Redundancy L2E
Release 4.1 03/08

2.1 Configuring HIPER-Ring Version 1

100 Mbit/s
Off
On
Full
1000 Mbit/s
On
On
13