Time
Parameters
Meaning
VLAN
The VLAN ID with which the device
sends its own frames (like PTP
Management frames or P2P
frames) to this port.
Note:
Also take the port's VLAN
setting
Static")
particular whether the VLAN
exists and if the the port is a
tagged or untagged member in
the VLAN.
none: The device always sends
PTP frames absent a VLAN tag,
even if the port is a tagged
member of the VLAN.
You can select VLANs that you
have already set up using of the
table row drop-down list.
VLAN Priority The VLAN priority (Layer 2,
IEEE 802.1p) with which the device
sends tagged PTP frames.
If you have set the VLAN ID to
none, the device ignores the VLAN
priority.
Table 54: Function IEEE 1588 / PTPv2 TC
Parameters
Meaning
Clock identifier
Device UUID of the TC (transparent
clock)
Current master When the Syntonize function is
enabled, the master's port UUID,
with which the device synchronizes
its frequency, is displayed.
A value consisting of zeros means
that:
Table 55: Status IEEE 1588 / PTPv2 TC
100
(see on page 127 "VLAN
into account here, in
the Syntonize function is
deactivated or
the device has not found a
master
3.3 PTP (IEEE 1588)
Possible values
Default setting
none, 0 - 4042 none
0 - 7
0
Possible values
Default setting
RM GUI L2E
Release 8.0 05/2013