Basic Settings
1.2 Modules (MS, PowerMICE,
MACH102 and MACH4000)
When you plug a module in an empty slot of a modular device, the device
configures the module with the port default settings. With the port default
settings loaded on the module, access to the network is possible. Deny
network access to modules by disabling the module slot. The device
recognizes the module and port configuration is possible but, the ports
remains in the disabled state.
Use the following work steps when deinstalling a module helps deny network
access using an empty slot.
 Remove module and update the graphical user interface by clicking
"Reload".
 The "Module Status" column for the removed module contains the value
configurable. The device also grays out the removed module in the
"Device View" frame of the
 Highlight the entry and click "Remove Module". The value in the "Module
Status" column changes to remove and the slot is empty in the "Device
View" frame in the
"Type" column for this entry contains the value none and the device
deletes the other module parameters.
 The selected "Enable" control box indicates that the slot is active. Disable
the entry to deny further network access through the unused slot.
Deactivating the control box disables the entry. After disabling an entry in
this table, the device places a red „X" over the slot in the "Device View"
frame of the
Basic Settings:System
Use the following work steps when installing a module in the slot.
 Place the module in the slot and update the graphical user interface by
clicking "Reload". The device automatically configures the module with
the default settings, detects the module parameters, and enters the
values in the table.
 The "Status" value of the module changes to physical.
 You allow access to the network through the module by selecting the
"Enable" control box.
22
Basic Settings:System
Basic Settings:System
1.2 Modules (MS, PowerMICE,
MACH102 and MACH4000)
dialog.