Diagnostics
Note: When you activate the logging of SNMP requests, the device sends
these as events with the preset severity notice to the list of syslog servers.
The preset minimum severity for a syslog server entry is critical.
To send SNMP requests to a syslog server, you have a number of options to
change the default settings. Select the ones that meet your requirements
best.
Set the severity for which the device creates SNMP requests as events to
warning or error and change the minimum severity for a syslog entry
for one or more syslog servers to the same value.
You also have the option of creating a separate syslog server entry for
this.
Only set the severity for SNMP requests to critical or higher. The
device then sends SNMP requests as events with the severity critical
or higher to the syslog servers.
Only set the minimum severity for one or more syslog server entries to
notice or lower. Then it may happen that the device sends a large
number of events to the syslog servers.
Figure 48: Syslog dialog
182
7.1 Syslog
RM GUI L2E
Release 8.0 05/2013