Hirschmann RS20 Reference Manual page 159

Gui graphical user interface industrial ethernet (gigabit) switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

Redundancy
Ring/Network Coupling dialog
Parameter
Selecting the
configuration
Coupling port
Port mode
Port State
Partner coupling port
IP address
Control port
Table 101:Ring/Network Coupling dialog
RM GUI L2E
Release 8.0 05/2013
Meaning
Depending on your local conditions, select "One-Switch coupling",
"Two-Switch coupling, Slave", "Two-Switch coupling, Master", "Two-
Switch coupling with control line, Slave" or "Two-Switch coupling with
control line, Master". These options are presented as buttons from left
to right.
Depending on the device type
only using DIP switches
only using software
using DIP switch and software
You will find details on the DIP switches on the devices in the
"Installation" user manual.
For devices configured only using DIP switches, you use these
switches to make the settings. In this case, the buttons in the dialog
are only for display purposes.
For devices without DIP switches, you only use the software to
make settings. You can select the configuration using the buttons.
For devices that can be configured using DIP switches and
software, you can activate or deactivate the DIP switches. If you
have activated the DIP switches, you cannot overwrite the DIP
switch settings using the software - settings that cannot be selected
using the software are grayed-out in the dialog.
To configure using the software, select the relevant Ring/Network
coupling constellation by pressing the corresponding button.
This is the port to which you have connected a redundant connection.
Note: Configure the coupling port and the ring ports, if there are any
ring ports, on different ports.
Note: To avoid continuous loops, the device sets the port status of the
coupling port to "off" if you switch off the function or change the
configuration while the connections are operating at these ports.
- active: You have switched the port on.
- stand-by: The port is in stand-by mode.
- active: You have switched the port on.
- stand-by: The port is in stand-by mode.
- not connected: You have not connected the port.
This is the port at which the partner has made its connection. It is only
possible and necessary to enter a port if "One-Switch coupling" is being
set up.
Note: Configure the partner coupling port and the ring ports, if there are
any ring ports, on different ports.
If you have selected "Two-Switch coupling", the device displays the IP
address of the partner here, once you have already started operating
the partner in the network.
This is the port to which you connect the control line.
6.2 Ring/Network Coupling
(see table
99), you make this setting:
159

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs30Rs40Ms20Ms30

Table of Contents

Save PDF