Security

2.2 SNMPv1/v2 Access Settings

With this dialog you can select access via SNMPv1 or SNMPv2. In the default
setting, both protocols are activated.
You can thus manage the device with Industrial HiVision and communicate
with earlier versions of SNMP.
Note: To be able to read and/or change the data in this dialog, log in to the
graphical user interface with the user name admin and the relevant
password.
In the "Index" column, the device shows the sequential number for the
access restriction.
In the "Password" column, you enter the password with which a
management station may access the device via SNMPv1/v2 from the
specified address range.
Note: Passwords are case-sensitive.
In the "IP Address" column, you enter the IP address which may access
the device. No entry in this field, or the entry "0.0.0.0", allows access to
this device from computers with any IP address. In this case, the only
access protection is the password.
In the "IP Mask" column, much the same as with netmasks, you have the
option of selecting a group of IP addresses.
Example:
255.255.255.255: a single IP address
255.255.255.240 with IP address = 172.168.23.20:
the IP addresses 172.168.23.16 to 172.168.23.31.