4
03.04
Coordinate system for
changing the actual value
display
References
4.2.4 Display axis feedrates
Axis
feedrate
or
Siemens AG, 2004. All rights reserved
SINUMERIK 840D/810D Operator's Guide HMI Embedded (BEM) – 03.04 Edition
4.2 General functions and displays
Function
Via the MD you can define whether the actual values are to be
displayed
•
without the programmed offsets = WCS or
•
including programmed offsets = SZS (settable zero offset
system).
Example:
Program
....
N110 X100
N120 X0
N130 $P_PFRAME=CTRANS(X,10)
N140 X100
N150 ...
/FB1/K2: Coordinate Systems...
Function
In operating mode "Jog" or "MDA" or "AUTO", you can display the
current feedrate, residual path information and the associated
override data.
Operating sequence
"Jog" mode is selected in the "Machine" operating area.
Press the "Axis feedrate" softkey:
•
On "MCS" the feedrate window with the current feedrates and
the residual path information, as well as the associated override
data, is displayed.
•
On "WCS", the feedrate window is displayed for the axes that
are subject to the interpolation, with current feedrate, residual
path information and path override, as well as for the other axes
with current feedrate, residual path information and single axis
override.
You can use the "Page" keys to display other axes if required.
Machine Operating Area
WCS display
SZS display
100
100
0
0
0
0
100
110
4
4-77