10) Cleaning of the 1st, 2nd, and 3rd Mirrors

11) Cleaning of the Lens

12) Replacement of the Cooling Fan Filters

1. Remove the Original Glass.
2. Remove two screws and the Reflector Mirror Assy.
3. Wipe clean the 1st Mirror with a soft cloth.
NOTE
Ensure that the mirror is not moved out of its correct
position when wiped clean.
1155D049AB
4. Wipe clean the 2nd and 3rd Mirrors with a soft cloth.
1155D050AA
1. Remove the Control Panel.
2. Remove the Original Glass.
3. Slide the Scanner all the way to the left.
4. Remove six screws and the board cover.
1075D051AB
5. Wipe clean the Lens with a soft cloth.
NOTE
When the Lens has been cleaned, perform Exp. Lamp
address and Orig. Size Adjust.
1155D052AA
1. Remove the Rear Cover.
2. Remove two rubber stoppers and the PH Section Cooling
Fan Filter.
1155D053AA
D-36