Touch Panel Display
I.R. & EDH Check
Function (EDH)
Pos./Zoom (FD)
Position (CD)
S-ADF Mode (CD)
Tech. Rep. Mode
Performs the following functions.
Automatically adjusts the zoom ratio and the scanning position in the FD
(sub-scanning) direction when the EDH is used and shows the results.
Note 1: Run this function after making sure that the result of the Skew
Check is within 1.0%.
Note 2: The Touch Panel shows "OK" if the adjustment value falls within
the specified range, and "NG" if it falls outside the range. It gives
the message of "Unable" if the adjustment sequence is abnormally
terminated.
<Procedure>
1. Load the chart in the EDH.
2. Press the Start key to start the measurement cycle.
3. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
Automatically adjusts the scanning position in the CD (main scanning)
direction when the EDH is used and shows the results.
Note 1: Run this function after making sure that the result of the Skew
Check is within 1.0%.
Note 2: The Touch Panel shows "OK" if the adjustment value falls within
the specified range, and "NG" if it falls outside the range. It gives
the message of "Unable" if the adjustment sequence is abnormally
terminated.
<Procedure>
1. Load the chart in the EDH.
2. Press the Start key to start the measurement cycle.
3. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
Adjusts the scanning position (CD) for a single feed scan.
Note: The Touch Panel shows "OK" if the adjustment value falls within the
specified range, and "NG" if it falls outside the range. It gives the
message of "Unable" if the adjustment sequence is abnormally ter-
minated.
<Procedure>
1. Insert the chart into the Single Feed Tray, which starts the measure-
ment cycle. (There is no need of pressing the Start key.)
2. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
S-42
I.R. & EDH Check