Removal of the Control Panel Unit (No. 3)
1. Remove the Right Upper Cover and Left Upper Cover.
2. Raise the Electronic Document Hander and remove the two screws.
3. Loosen the four screws at the right and left and one at the front illustrated below.
4. Loosen the two screws marked with
ground wire connector, and then remove the Control Panel Unit.
* To remove only the control panel, loosen two screws marked with
two connectors and one ground wire connector.
A
, raise the control panel, unplug two connectors and one
A
D-8
A
, raise the control panel, unplug
A
1155D004AC