13. Remove the E-ring and gear. Remove one screw and the bias contact plate. Then, remove the
bushing for the Developer Conveying/Agitating Screw.
14. Remove three screws and the cord clamp.
15. Remove two screws and the bushing for the Bucket Roller.
16. Remove two screws each at the front and rear and the 1st/2nd Sleeve/Magnet Rollers Assy.
17. Remove the Toner Replenishing Sleeve/Magnet Roller and the bushings on the front and rear.
18. Disassemble the 1st/2nd Sleeve/Magnet Rollers Assy as illustrated below.
1075D226AB
NOTE
When reinstalling the bushing, twist it into position.
1155D088AA
NOTE
When reinstalling the bushings, twist it into position.
1075D225AA
NOTE
When reinstalling the bushings, twist it into position.
D-53