6) Adjustment of the Paper Exit Timing Belt

7) Adjustment of the Scanner Motor Timing Belt

8) Adjustment of the 3rd Drawer Timing Belt

1. Remove the Rear Cover.
2. Remove five screws and the Fusing Unit Drive Assy.
1155D136AA
3. Loosen the screw by which the Tension Lever is mounted
as shown on the left and then re-tighten it.
1155D138AA
1. Remove the Rear Cover and Upper Rear Cover.
2. Loosen four screws on the Scanner Motor mounting
bracket and then re-tighten them.
1155D137AA
1. Pull out the 3rd Drawer and remove it.
2. Lift up the Main Tray and remove the two screws by which
the Shift Tray is fixed.
Be careful, the Main Tray wire easily comes off at
reassembly.
1075D311AA
3. Release the lock by pressing the lock lever of the Shift Tray
using a screwdriver, etc., as shown on the left.
4. Remove the Shift Tray.
1075D312AB
D-74