22. Disassemble the Upper Fusing Unit as illustrated.
NOTE
When the Upper Fusing Roller has been removed, clear the count of Fusing Roller of PM Counter
4/4 available from Tech. Rep. mode.
19. Unplug the connectors of the Cleaning Web Drive Motor
and Upper Fusing Roller Thermistor.
20. Remove four shoulder screws, one washer, and the Upper
Fusing Unit.
1155D101AA
21. Remove two screws and the Lower Paper Separator
Fingers Assy.
1075D253AA
23. Remove one screw, one shoulder screw, and the Pre-
Fusing Guide Plate.
1155D103AA