<Control>
The Image Transfer/Paper Separator corona wires are automatically cleaned under
the following conditions. The cleaning function is, however, disabled if the "Charge
Wire Cleaning" function of "System Input" available from the Tech. Rep. mode has
been set to "Off".
(1) A period of 500 msec. has elapsed after Power Switch has been turned ON.
(2) The number of copies made exceeds 10K after the Power Switch has been
turned ON and 10 minutes elapse after the last copy cycle has been com-
pleted.
(3) An Image Transfer/Paper Separator Coronas malfunction, which has been
detected, is reset.
(4) A misfeed/malfunction, which has been detected, is reset with a sheet of paper
remaining at the area near the Image Transfer/Paper Separator Corona.
CONTROL SIGNAL
M8
CONTROL SIGNAL UNBLOCKED
PC17
FORWARD
PJ3A-9~12A
PJ3A-4B
M-105
BACKWARD
Pulse Output
BLOCKED
H
L
1155T31MCB
WIRING DIAGRAM
C-7
WIRING DIAGRAM
C-7