C0500, C0510
Step
1
Remove the Fusing Unit Front Cover and
then turn ON the Power Switch. Does H1
turn ON at this time?
2
Does H2 turn ON when the malfunction is
reset with the surface temperature of the
Lower Fusing Roller at 135°C as indicated
on "Level History" available from the Tech.
Rep. mode?
3
Is TH1 or TH2 installed properly?
4
Is TH1 or TH2 dirty?
5
Measure the resistance of TH1 (across
CN28-2 and 3 on the Fusing Unit end). Is
the measurement infinity?
6
Measure the resistance of TH2 (across
CN32-2 and 3 on the Fusing Unit end). Is
the measurement infinity?
7
Does the voltage across PJ8A-3B on PWB-
A and GND change from DC5V to DC0V
when the Power Switch is turned ON?
8
Does the voltage across PJ8A-4B on PWB-
A and GND change from DC5V to DC0V
when step 2 is performed again?
9
Unplug CN4 (8P). Is there continuity
across CN4-1 and 4 on the Fusing Unit
end?
10
Unplug CN4 (8P). Is there continuity
across CN4-5 and 8 on the Fusing Unit
end?
11
Is the voltage across PJ4C-3A on PWB-C
and GND, and across PJ4C-2A on PWB-C
and GND, DC5V?
Check Item
Result
NO
Check step 7 and onward.
NO
Check step 8 and onward.
NO
Correct the installation of TH1 or TH2.
YES
Clean or change TH1 or TH2.
YES
Change TH1.
YES
Change TH2.
NO
Change PWB-A.
NO
Change PWB-A.
NO
Check H1 or TF1 for continuity.
NO
Check H2 or TF2 for continuity.
YES
Change PWB-A, SSR1 or SSR2.
NO
Cange PWB-C.
T-56
Action