Minolta Di 620 Manual page 209

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

Touch Panel Display
Fusing (°C) Input
Image Density
ATDC Control
<IR>
Touch Panel Display
Zoom (CD)
Zoom (CD) Manual
Scale (FD)
Scale (CD)
Exp. Lamp Adjust
Exp. Lamp address
<EDH>
Touch Panel Display
Zoom (FD) EDH
Tech. Rep. Mode
Setting (The default is
Set the temperature for fusing temperature control of the printer.
3
195°C
Set the image density for the printer.
Current: Displays the current ATDC control voltage.
Set: Set the ATDC control voltage.
Note: If the value for "Set" is to be changed, be sure to record the current
setting value.
Setting (The default is
Set the correction value for the zoom ratio in the CD direction.
(Smaller)
Set the correction value for the zoom ratio in the FD direction.
(Smaller)
Set the correction value for the Original Length Scale position in the FD
direction (scanning position).
Set the correction value for the Original Width Scale position in the CD
direction (scanning position).
Set the intensity regulating level of the Exposure Lamp.
Note: This function is only for factory setting and should never be used in
the field.
Set the starting address for light intensity monitoring.
Note: This function is only for factory setting and should never be used in
the field.
Setting (The default is
Set the correction value for the zoom ratio in the FD direction when the
EDH is used.
S-54
Adjust
Highlighted
2
190°C
(−3 to +3)
(0)
(0 to 9.4)
(7V)
Highlighted
0.990
1.000
0.990
1.000
(−7.0 to +7.0)
(0.0)
(−12.0 to +12.0)
(0.0)
(48 to 100)
(376 to 4920)
(2640)
Highlighted
(0.980 to 1.020)
(1.000)
.)
1
180°C
.)
1.010
(Greater)
1.010
(Greater)
.)

Advertisement

Table of Contents
loading

Table of Contents