Minolta Di 620 Manual page 298

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

Section
Step
7
Are the Comb Electrode and grid mesh dirty?
Engine
8
Is the Upper Fusing Roller dirty with foreign
matter?
1
Are the Original Glass, mirrors and lens dirty
IR
with foreign matter?
1
Select "Tech. Rep. Mode," "Function," and
"Image Memory," in that order. Does "NG"
appear when "Input Image" is then run?
2
Select "Tech. Rep. Mode," "Function," and
Memory
"Image Memory," in that order. Does "NG"
appear when "I.R.
run?
1155SBT050306A
6) Black Spots
Section
Step
1
Is the PC Drum surface dirty with foreign mat-
ter?
2
Are the PC Drum Paper Separator Fingers
dirty with foreign matter?
Engine
3
Is the Upper Fusing Roller dirty with foreign
matter?
4
Is there caked toner in the Developing Unit?
5
Is the T/C ratio on the high side?
1
Select "Tech. Rep. Mode," "Function," and
"Image Memory," in that order. Does "NG"
appear when "Input Image" is then run?
2
Select "Tech. Rep. Mode," "Function," and
Memory
"Image Memory," in that order. Does "NG"
appear when "I.R.
run?
Check Item
→ ←
→ ←
Mem.
Prn" is then
Check Item
→ ←
→ ←
Mem.
Prn" is then
T-83
Result
Action
YES
Clean or change the PC
Drum Charge Corona.
Check the toner suction
mechanism for operation.
YES
Clean or change the Upper
Fusing Roller.
YES
Clean the Original Glass,
mirrors and lens.
YES
Change PWB-B.
YES
Change PWB-B.
Result
Action
YES
Clean or change the PC
Drum.
YES
Clean or change the sepa-
rator fingers.
YES
Clean or change the Fus-
ing Roller.
YES
Change the developer.
YES
Change the T/C ratio and
make a copy.
YES
Change PWB-B.
YES
Change PWB-B.