Registration (Cd - Minolta Di 620 Manual

Hide thumbs Also See for Di 620:
Table of Contents

Advertisement

10) Registration (CD)

Requirement
NOTE
This adjustment must be made after the PH has been replaced and following the adjustment of the
reference Zoom (FD) Adjust.
Adjustment Procedure
1. Call the Adjust mode to the screen.
2. Touch [Printer] and [Registration (CD)], in that order.
3. Select the paper source to be checked and adjusted.
4. Press the Start key to let the copier produce a test pattern.
5. Check to see if width A on the test pattern is up to the specifications. If it is outside the specified
range, perform the following adjustment steps.
6. Use the 10-key Pad to change the setting value.
Setting Instructions
If width A is longer than the specifications, make the setting value smaller than the current one.
If width A is shorter than the specifications, make the setting value greater than the current one.
1) Use the following equation to find the setting value:
Specification (5.0 mm) - measurement = setting value
2) If a single adjustment procedure does not successfully bring width A into the specified range, try
another setting value.
7. Touch the [Enter] key to validate the setting value.
Caution
Be sure to touch the Enter key before returning to the normal operation mode. If the Panel Reset
Key is used, the previous setting remains valid.
Width A on the test pattern output should fall within the
following range.
Specification
5.0 ± 0.5 mm
1155D154AB
1155D196CC
D-91
Adjust Mode
Registration (CD)
3
4
5
6
7
8
9
0
C
Use to clear the setting value.
Use to enter the setting value.
Setting Range
-8.2 to +8.2
Use to chage the + or - sign.
1155D189CA