Alarm Window; Interrogator Window - Christie CP2220 User Manual

Hide thumbs Also See for CP2220:
Table of Contents

Advertisement

6.6

Alarm Window

When an alarm occurs, an Alarms window with a red border appears with a description of the alarm condition,
state, and time and date of the alarm. The window only displays alarms you have not previously
acknowledged. To acknowledge an alarm and remove it from the Alarms window, click Acknowledge. To
view all alarms, tap Menu > Status > All Alarms in the left pane.
6.7

Interrogator Window

To open the Interrogator window you need Operator, Administrator, or Service permissions. Tap Menu >
Diagnostics > Interrogator.
When you run the interrogator, you cannot modify cinema projector settings. Image disruption can occur if you
run the interrogator during a show. If a failure occurs, run the interrogator to capture valuable diagnostic
information before you correct the issue or restart the cinema projector.
Use the Interrogator window to retrieve log files and current configuration information in a single file. Select
Basic Mode to return log files, or select Enhanced Mode to return log files and registered batch files. Select
Download to USB to copy the log and batch files to a USB drive.
NOTE: Log files are compressed into a .7z or 7-zip file format. A tool for opening these archives can be
downloaded from
CP2220 User Manual
020-100420-08 Rev.1 (5-2014)
Figure 6-4 Alarm Window
http://www.7-zip.org.
Section 6: Cinema Projector Menus
6-11

Advertisement

Table of Contents
loading

Table of Contents