Appendix C
Error
number
Cal: drive occupied. The tape
drive could not be calibrated
94
because a cartridge was loaded
in the drive.
Drive removed. A drive was
removed without using the Tape
95
Drive Service Menu while the
library was powered on.
Drive added. A drive was
installed without using the Tape
96
Drive Service Menu while the
library was powered on.
M ove interrupted. The
movement of the robot was
interrupted.
100
Drive only command. The
attempted command could not
101
be executed because the
specified element was not a
drive.
Drive did not eject. The library
was unable to pick a cartridge
104
because the cartridge did not
eject from the tape drive.
256
Description
Corrective action
Eject the cartridge from the tape drive
and remove it manually (see
Reissue the calibration command.
Contact your service provider.
Power the library off and then on.
If the error persists, contact your
service provider.
Move the robot toward the front of the
library.
If there is a cartridge in the gripper,
manually remove the cartridge and
return it to its original slot.
Make sure the library and tape drives
are not being used by any host, then
reset the library from the operator
panel.
Select a drive and reissue the command.
Eject the cartridge from the tape drive
and remove it manually (see
If the error persists, contact your
service provider.
page
95).
page
95).
Exabyte X200
Need help?
Do you have a question about the X200 Library and is the answer not in the manual?
Questions and answers