Appendix C
The following table lists the numbered library hardware error
conditions in numerical order.
Error
number
Dropped a cartridge. The robot
dropped a cartridge.
10
Source empty. There is no
11
cartridge in the source location.
Destination full. A cartridge
12
already exists in the destination
location.
Put failure. The robot could not
successfully place a cartridge
13
because of mechanical
problems.
Pick failure. The robot could not
successfully pick a cartridge
14
because of mechanical
problems.
15
No source element; No dest
element. No magazine is
16
installed in the selected location.
246
Description
Corrective action
Œ
Manually return the cartridge to its
original slot.
CAUTION: Do not try to put the cartridge
back in the robot gripper.
Œ
Make sure the library and tape drives
are not being used by any host, then
reset the library from the operator
panel.
Œ
If the error persists, contact your
service provider.
Install a cartridge in the source location or
redirect the robot to another location.
Remove the cartridge from the
destination or redirect the robot to
another location.
Œ
Make sure there is nothing blocking
the robot.
Œ
If the error persists, contact your
service provider.
Install a magazine or redirect the robot to
another location.