8-6 ELECTRICAL SYSTEM
CHARGING SYSTEM
Generator
TROUBLESHOOTING
Battery runs down quickly.
Check accessories which use excessive
amounts of electricity.
No accessories
Check the battery for current
leaks. (! 8-7)
No current leaks
Measure the charging voltage
between the battery term nals.
(! 8-8)
Incorrect
Measure the continuity of
the generator coil.
(! 8-8)
Continuity
Continued on next page
Regulator / rectifier
B
Y
Y
B
Y
B
Accessories
are installed
Current leaks
Correct
No continuity
B/R
Ig.switch
B/R
Fuse
IC
SCR
• Remove accessories.
• Short circuit of wire harness
• Faulty electrical equipment
• Faulty battery
• Abnormal driving condition
• Faulty generator coil or
disconnected lead wires