IGNITION COIL RESISTANCE
• Remove the fuel tank. (&5-3)
• Disconnect the ignition coil lead wires and plug caps.
Measure the ignition coil resistance in both the primary and sec-
ondary windings. If the resistance is not within the standard range,
replace the ignition coil with a new one.
" 09900-25008: Multi circuit tester set
* Tester knob indication: Resistance (Ω)
# Ignition coil resistance
: 2 – 6 Ω Ω (Terminal – Terminal)
Primary
Secondary : 15 – 30 kΩ (Plug cap – Terminal)
PICKUP COIL PEAK VOLTAGE
• Remove the two seats. (&7-2)
• Disconnect the wire harness coupler 1 at the ignitor.
NOTE:
Make sure that all of the couplers are connected properly.
Measure the pickup coil peak voltage in the following procedure.
• Connect the multi circuit tester with the peak volt adaptor as
follows.
+ Probe: Blue/White lead wire
- Probe: Green lead wire
" 09900-25008: Multi circuit tester set
!
Before using the multi circuit tester and peak volt adap-
tor, be sure to refer to the appropriate instruction manual.