7.1 ELECTRICAL SYSTEM
CHARGING SYSTEM
INSPECTION
CHARGING OUTPUT
CHECK
Remove
the
seat.
Start the
engine and
keep it running at
5 000 rlmin
with lighting switch turned ON (HI position).
Using the pocket tester, measure
the DC voltage
between the battery terminal @ and
Q
.
T f the tester reads under 14V or aver 15.5V, check
the
AC generator no-load performance and regula-
tor/rectif ier.
When making this
test,
be sure that the
bat-
STD charging
output
14
-
15.5
V
(DC)
at
5 000 dmin
AC GENERATOR NO-LOAD PERFORMANCE
Disconnect the three lead wires from the AC
generator
terminal.
Start the engine and keep it running at
5
000
r/min.
Using the pocket
tester, measure
the AC voltage
between the three lead wires.
If the tester reads under 80V,
the
AC generator is
faulty.
09900
-
25002
S t 0 No-load
performance
I
More
than
80V (AC)
at
5 000
rlmin
Pocket
tester
IG. switch
--