Suzuki VL800 Service Manual page 241

Hide thumbs Also See for VL800:
Table of Contents

Advertisement

REGULATOR/RECTIFIER
• Remove the secondary gear case cover.
• Disconnect the regulator/rectifier couplers.
Measure the voltage between the lead wires using the multi cir-
cuit tester as indicated in the table below. If the voltage is not
within the specified valve, replace the regulator/rectifier with a
new one.
# 09900-25008: Multi circuit tester set
) Tester knob indication: Diode test (*
B/R
B/R
1
2
B/R
0
1
B/R
0
2
B
1
B
2
B
3
B/W
1
B/W
2
More than 1.4 V (tester's battery voltage)
NOTE:
If the tester reads under 1.4 V when the tester probes are not
connected, replace the battery of multi circuit tester
* )
+ Tester probe
B
B
B
1
2
3
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
0.4 – 0.7 0.4 – 0.7 0.4 – 0.7 0.5 – 1.2 0.5 – 1.2
Unit: V
B/W
B/W
1
2
0.4 – 0.7 0.4 – 0.7
0.4 – 0.7 0.4 – 0.7
0.4 – 0.7 0.4 – 0.7
0
0
WIRE COLOR
B: Black, B/R: Black with Red tracer,
B/W: Black with White tracer
ELECTRICAL SYSTEM 8-9
B
2
B
1
B
3
B/W
1
B/R
1
B/R
2
B/W
2

Advertisement