Is the voltage OK?
• G/B, G/W, R or B/Br wire open or shorted to
ground, or poor L, 3, 6 or D connection.
• If wire and connection are OK, intermittent trou-
ble or faulty ECM.
YES
• Recheck each terminal and wire harness for
open circuit and poor connection.
• Replace the ECM with a known good one, and
inspect it again.
If check result is not satisfactory, replace IAP sen-
NO
sor with a new one.
4) After repairing the trouble, clear the DTC using SDS tool.
($14-39)
Output voltage (Vcc voltage 4.5 – 5.5 V, ambient temp. 20 –
30 °C, 68 – 86 °F)
ALTITUDE
(Reference)
(ft)
(m)
0
0
2 000
610
2 001
611
5 000
1 524
5 001
1 524
8 000
2 438
8 001
2 439
10 000
3 048
ATMOSPHERIC
PRESSURE
(mmHg)
kPa
760
100
707
94
707
94
634
85
634
85
567
76
567
76
526
70
OUTPUT
VOLTAGE
(V)
3.4 – 4.0
2.8 – 3.7
2.6 – 3.4
2.4 – 3.1
VL800K5 ('05-MODEL)
14-51