18-54 VL800/C/TK9 ('09-MODEL)
ISC VALVE PRESET AND OPENING
INITIALIZATION
When removing or replacing the ISC valve, set the ISC valve in
the following procedures:
1) Turn the ignition switch ON.
2) Set up the SDS tool. (Refer to the SDS operation manual for
further details.)
 09904-41010: SDS set tool
99565-01010-017: CD-ROM Ver.17
3) Click "Active control".
4) Click "ISC learned value reset" 1.
5) Click "Reset" button 2 to clear the ISC learned value.
NOTE:
The learned value of the ISC valve is set at preset position.
6) Close the SDS tool.
7) Turn the ignition switch OFF.
NOTE:
The ISC valve opening initialization is automatically started after
the ignition switch is turned OFF.