Precautions In Servicing; Electrical Parts - Suzuki VL800 Service Manual

Hide thumbs Also See for VL800:
Table of Contents

Advertisement

14-18
VL800K5 ('05-MODEL)

PRECAUTIONS IN SERVICING

When handling the component parts or servicing the FI system,
observe the following points for the safety of the system.

ELECTRICAL PARTS

CONNECTOR/COUPLER
• When connecting a connector, be sure to push it in until a
click is felt.
• With a lock type coupler, be sure to release the lock when dis-
connecting, and push in fully to engage the lock when con-
necting.
• When disconnecting the coupler, be sure to hold the coupler
body and do not pull the lead wires.
• Inspect each terminal on the connector/coupler for looseness
or bending.
• Inspect each terminal for corrosion and contamination.
The terminals must be clean and free of any foreign material
which could impede proper terminal contact.
• Inspect each lead wire circuit for poor connection by shaking it
by hand lightly. If any abnormal condition is found, repair or
replace.
• When taking measurements at electrical connectors using a
tester probe, be su e to insert the probe from the wire harness
side (backside) of the connector/coupler.
1 Coupler
2 Probe
Click
Click

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intruder vl800

Table of Contents