Replacing The Lens - Christie CP2208 User Manual

Hide thumbs Also See for CP2208:
Table of Contents

Advertisement

8. To confirm that the filter is dry, place it over a dry paper towel and shake it. If the paper towel
remains dry, the filter can be installed in the projector.
9. Record the date the filter was cleaned.
10. Replace the filter following the instructions for the specific filter. See
filter on page 91

Replacing the lens

The lens seals the projection head, preventing contaminants from entering the main electronics
area. Do not operate the projector without a lens installed. Install a lens plug when you install or
transport the projector.
1. Tap and hold the red power button
projector off.
2. Allow the lamp to cool for a minimum of 15 minutes.
3. Disconnect the projector from AC power or turn the circuit breaker off.
4. Remove the lens surround.
5. Install the lens cap and turn the lens clamp to the open position with a hex key.
6. If necessary, remove the two cap screws securing the lens to the lens mount using a hex key.
7. Pull the lens out of the lens mount and then install a small lens cap on the rear of the lens.
8. Remove the small rear cap from the new lens. Keep the front cap on.
9. Align the tabs on the lens plate with the lens mount. Insert the lens until it connects with the
magnets on the mount. When the lens contacts the magnetic plates it is seated correctly.
10. Secure the lens clamp by rotating it clockwise with a hex key.
11. Tighten the lens mount cap screws for added stability.
12. Replace the lens surround.
13. Remove the lens cap from the front of the lens.
CP2208 User Manual
020-101916-02 Rev. 1 (08-2015)
or
Inspecting the light engine compartment filter
on the TPC Main panel to turn the lamp and
Maintenance
Inspecting the card cage
on page 91.