Adjusting vertical boresight angle

Warning! Failure to comply with the following could result in serious injury.
A boresight adjustment should only be made when the image cannot be focused uniformly on the
screen by aligning the projector to the screen and focusing the lens. When adjusting boresight, you
must maintain the boresight distance from the lens to the prism plane set by Christie. For example,
when you move the top screw outward, turn the bottom two boresight screws to maintain the overall
distance.
Caution! Failure to comply with the following could result in minor or moderate injury.
Only adjust vertical boresight 1/8 of a turn or less at one time to maintain optimal lens performance
(factory setup of absolute lens distance to the prism). It is critical that each turn of the cap screws is
tracked to ensure adjustments are accurate.
It is recommended that you complete a top and bottom boresight adjustment before adjusting the
horizontal boresight.
1. Remove the lens surround.
2. Display the DC2K Framing2 test pattern:
a. On the touch panel controller, tap the Test Pattern (
b. Tap DC2K Framing 2.
3. Loosen the set screw (B).
4. Turn the vertical cap screw (A) 1/8 of a turn counter-clockwise.
5. Adjust both left and right horizontal adjusters by half the number of turns, in the opposite
direction of the vertical adjust. For example, if the vertical adjust cap screw was turned 1/8 of a
CP2208 User Manual
020-101916-02 Rev. 1 (08-2015)
Cap Screw - Adjusts top and bottom boresight
A
Set Screw - Locks or unlocks the cap screw
B
Adjusting the Image
) icon in the task bar.
A
B
37