2. Wrap a lens tissue around a swab and soak it in lens cleaning solution. The tissue should be
damp but not dripping.
3. Gently wipe the surface using a figure eight motion. Repeat until the blemish is removed.

Replacing the lamp

Danger! Failure to comply with the following results in serious injury.
• Lamp replacement must be performed by a qualified service technician.
• EXPLOSION HAZARD. Wear authorized protective clothing whenever the lamp door is open and
when handling the lamp. Never twist or bend the quartz lamp body. Use the correct wattage lamp
supplied by Christie.
• Ensure those within the vicinity of the projector are also wearing protective safety clothing.
• Never attempt to remove the lamp when it is hot. The lamp is under pressure when hot and may
explode, causing personal injury, death, or property damage. Allow the lamp to cool completely
before replacing it.
Warning! Failure to comply with the following could result in serious injury.
Improper installation of the lamp can damage the projector.

Removing the existing lamp

1. Tap and hold the red power button
the lamp and projector off.
2. Allow the lamp to cool for a minimum of 15 minutes.
3. Unplug the projector.
4. Disconnect the touch panel controller (TPC) communication cable from the rear of the projector.
5. Remove the TPC from the rear of the projector.
6. Put on your protective clothing and face shield.
7. Insert the key in the lock on the lamp door, turn the key, and then open the lamp door. Do not
place heavy objects on the open lamp door.
CP2208 User Manual
020-101916-02 Rev. 1 (08-2015)
on the touch panel controller (TPC) Main panel to turn